Pierburg "CWA100-3“

Pierburg's new electric water pump in the medium capacity range.


  • Robust and innovative design
  • Brushless canned motor
  • Integrated variable speed controller
  • Controllable via PWM
  • Reliable and maintenance free
  • High delivery rates

Pierburg CWA100-3

The CWA100-3 is a successor of the CWA100-2 we are also offering. The dimensions and the weight is nearly the same.
New is the freshly designed impeller housing with slightly shorter water in and outlets and the bigger
electrical connector. This improves the handling of bigger cable diameters significantly.
Suitable for instance for intercooling in combustion engine vehicles and cooling of various systems in electrical vehicles.


Specifications:

  • Name: "Pierburg CWA100-3"
  • Operation voltage: 8-16 volts
  • Weight: approx. 1.0 kg
  • Current consumption: 8.5A max. / (approx. 0.2mA in standby mode)
  • Nominal diff. pressure: ≥ 0.75 bar *
  • Flow rate: approx. 30-35 l/min @ 0.75bar / 40-45 l/min @ 0.50bar
  • Speed: approx. 7000 rpm
  • Temperature range: -40°C – 110°C (water) / -40°C – 120°C (ambient)
  • Protection: IP 67 + IP 69 K

Part numbers:

  • Pierburg: 7.04934.54.0
  • VAG: 4N0965567


Downloads:

Datasheet:
CWA100-3 Datasheet EN (pdf)

3D CAD files:
CWA100-3 3D CAD (zip)

PWM Info:
CWA PWM Info (pdf)


Technical drawing:

drawing

Flow rate:

flowrate

Overview:

flowrate

Know-how:

* Pump pressure is not the same as the system pressure.
Those pumps can of course be used in normal automotive cooling systems with system pressures
in the range of 0.8 to 1.2 bar for instance.
The pump pressure or differential pressure expresses the ´resistance´ of which the pump has to work against.
Tip: A mechanical thermostat is responsible for about half of that resistance. (in most cars)


Controller:

We will gladly provide you with our controller (tinyCWA) to control the pump.
Just write us an email in this matter or take a look at our online store.
There you will also find product bundles and accessories. :-)